Suppliers with verified business licenses
number | Project requirements | Performance indicators |
1. | Subject | PVC hose |
2. | Features | Pressure resistance, burst test |
3. | Test medium | Water/prepared by customer |
4. | Test pressure | 1~8MPa/Can be set in the range |
5. | Pressure test accuracy | ±0.5%F.S |
6. | Pressure control accuracy | ±2%F.S |
7. | Boost rate | 10KPa/S(Set the boost rate as needed) |
8. | Medium temperature | Room temperature |
9. | Ambient temperature | Room temperature |
10. | Simultaneous test pieces | 1 item |
11. | control method | Automatic control(PLC control, touch screen set test parameters) |
The main components | Detailed composition | Function description |
power system | Low-pressure compressed air (user-supplied), water tank, gas-liquid booster pump, filter and piping | Providing a pressure source for the test bed booster system; |
Drive gas source treatment | Drive air line with two parts, filter | Filter and oil mist treatment for drive line gases |
Test cabinet | The frame structure is welded for ordinary carbon steel profiles | Surface anti-rust and spray decoration treatment |
Control System | Composed of pneumatic proportional valve, solenoid valve, high pressure gas control needle valve, etc. | Controlling the pressure of the gas source to control the pressure of the high pressure liquid from the gas-liquid booster pump |
Liquid filled exhaust system | The system consists of a water pump, a filter, and a solenoid valve. | Manual exhaust, close the charge pump and solenoid valve after the test piece is filled with the test medium |
Test piece installation room | The test room consists of a liquid filling system.. | Workpiece installation, -- station design |
Electrical control system | Electrical control panel in the electrical cabinet | |
measuring system | Pressure sensor, pressure gauge, etc. | Data measurement for pressure |
Control System | PLC control: PLC controller is installed in the operation cabinet, and the external touch screen is used for control operation; | The test setup and operation are completed by touch screen operation, the control program is mature, the interface is humanized, and the operation reliability is high; |