OMT-Series
This series of pump has double stage. It can amplify extremely low pressure into very high pressure. The drive gas pressure≤8bar. The rage of inlet gas pressure is 0.5-10bar. The maximum pressure can be up to 80Mpa. The pump is made of aluminum alloy and stainless steel.
The diameter of its drive piston is 160mm. Both pump heads can cool the exhaust gas.
I.Introduction OMD-Series
OMD series gas booster pump is a single-stage booster pump. In order to achieve the required pressure, the input air pressure at the gas inlet needs to be pre increased to a certain extent. The pre increased pressure varies with the maximum pressure. The maximum pressure can be increased to 80MPa. The reversing mode of this series of pumps is the same as that of OMA series. The difference is that this series of pumps are double head pumps based on OMA series. The whole pump is made of aluminum alloy and stainless steel. The diameter of the driving piston of this series of pumps is 160mm, the driving air pressure is ≤ 8bar, and the pump heads at both ends are equipped with exhaust cooling. When leaving the factory, two inlets and two outlets can be connected according to the user's requirements.
Type |
Pressure ratio |
Min. Gas Inlet Pressure PA(bar) |
Max. Gas Inlet Pressure PA(bar) |
Max. Allowed Outlet Pressure PB(bar) |
Outlet Pressure Calculate Formula PB |
Gas Inlet |
Gas Outlet |
Max. Flow Ln/min @PL=6bar |
OMD05 |
5:1 |
1bar |
40bar |
40bar |
5PL+PA |
ZG1/2 |
ZG1/2 |
680@PA=6 |
OMD10 |
10:1 |
5bar |
80bar |
80bar |
10PL+PA |
ZG1/4 |
ZG1/4 |
372@PA=6 |
OMD25 |
25:1 |
10bar |
200bar |
200bar |
25PL+PA |
ZG1/4 |
ZG1/4 |
154@PA=20 |
OMD40 |
40:1 |
15bar |
320bar |
320bar |
40PL+PA |
ZG1/4 |
ZG1/4 |
92@PA=20 |
OMD60 |
60:1 |
25bar |
480bar |
480bar |
60PL+PA |
ZG1/4 |
ZG1/4 |
115@PA=40 |
OMD100 |
100:1 |
35bar |
800bar |
800bar |
100PL+PA |
ZG1/4 |
M14*1.5 |
74@PA=40 |
PL=drive pressure PA=inlet gas pressure PB=outlet gas pressure
.Layout of Machine for reference.
III..Technical Parameter
Machine Name |
Air Driven Hydrogen Booster Pump |
Model |
OMD-25 |
Booster Medium |
gas |
Pressure ratio |
25:1 |
Inlet pressure |
Min.10bar, max. 200bar |
Outlet pressure |
Max.200bar |
Max.2900 psi |
Flow L/Min |
308L/min( at inlet 40bar,driven air 6bar min.) |
Outlet Pressure Calculate Formula |
25PL+PA |
connections |
Drive connection |
ZG1/4" |
Inlet |
ZG1/4'' |
Outlet |
ZG1/4'' |
Net weight KG |
21KGS |
GROSS WT |
29KGS |
Packing size |
690*480*350mm |
Wooden cases |
Export standard fumigation wooden cases |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
PL=drive pressure PA=input gas pressure PB=output gas pressure
Key features include:
- Compressed Air driven - no electricity required (connect to normal air compressor)
- In order to extend the lifetime of the pump, the driving air pressure should
not be higher than 8 bar
- No airline lubricator required
- Hydrocarbon free - separation between air and gas sections
- Pressures to 80Mpa (11,600 psi)
- Wide range of models with different ratios
- Built-in-cooling on most models
- Easy to install, operate and maintain
- Best price / performance ratio
- No heat, flame or spark risk and explosion proof
- Automatic pressure holding, whatever the cause of the pressure drop, the Suncenter pump will automatically start, keep the loop pressure constant
- Applicable gas: Argon/Helium/Hydrogen/Oxygen/NO2/CH4/LNG/LPG/CNG/FM200 etc.
OMT series gas booster pumps(Double acting ):
DGD series pumps are double acting, with single air driven heads type.
- OMT pumps are available with high quality seals, which provide significantly better service life
- Double pump heads with exhaust cooling devices.
- All components in contact with the gas are made of stainless steel.
- Pipes mounting way are available as customized.
- Pressure test with gas
- Gas transfer and filling
(Argon/Helium/Hydrogen/Oxygen/Nitrogen/CO2/NO2/CH4/LNG/LPG/CNG/FM200 etc.)
- Charging of gas cylinder and accumulator with nitrogen
- Supply for isolating gas systems
- Gas assisted injection molding
- Transfer of oxygen cylinders
- Charging of breathing air bottles
- Leak test
- Hydrostatic Testing for valves, tanks, pressure vessels, pressure switches, hoses, pipes and tubing, pressure gauges, cylinders, transducers, well casings, BOPs, gas bottles and air craft components
- Safety valve adjusting
Exhibition d Customer Visit
Q1. Where is your factory located ? How can I visit there?
Our factory is located in Jinan city, Shang dong Province, China. We can go to Jinan airport and wait for your arrival.
Q2 : Do you have stock for all items?
A:In general, we have some stock, while if you need a bulk order, we still need time to produce it. Of course, we will inform all details you before your payment.
Q3. How long can be finished the goods ?
A : Sample order : within one week ;
Large order : 15-25 days ; According to your purchase quantity.
Q4. At which port do you usually ship the good?
We usually ship goods via Qingdao port of China.
Q5 : What is payment terms ?
A: Sample order : 100% full payment before start to production;
Large order : 30% deposit first, 70% pay after see the BL copy ;
Q6: Can give free sample ?
A : Free : if small spare parts and the cost not too much is ok ;
Not Free : the cost expensive and all the machine can not be free ;